Datasheet

www.ti.com
0 V
–12 V
+12 V
Current
OUTP
Differential Voltage
Across Load
OUTN
TPA3007D1 MODULATION SCHEME
TPA3007D1
SLOS418D SEPTEMBER 2003 REVISED MARCH 2008
Figure 14. Traditional Class-D Modulation Scheme's Output Voltage and Current Waveforms Into an
Inductive Load With No Input
The TPA3007D1 uses a modulation scheme that still has each output switching from ground to V
CC
. However,
OUTP and OUTN are now in phase with each other with no input. The duty cycle of OUTP is greater than 50%
and OUTN is less than 50% for positive output voltages. The duty cycle of OUTP is less than 50% and OUTN is
greater than 50% for negative output voltages. The voltage across the load is 0 V throughout most of the
switching period, greatly reducing the switching current, which reduces any I
2
R losses in the load. (See
Figure 15 ).
Copyright © 2003 2008, Texas Instruments Incorporated Submit Documentation Feedback 11
Product Folder Link(s): TPA3007D1