Datasheet
TPA3004D2
www.ti.com
SLOS407E –FEBRUARY 2003–REVISED JANUARY 2011
BASIC MEASUREMENT SYSTEM
This application note focuses on methods that use the basic equipment listed below:
• Audio analyzer or spectrum analyzer
• Digital multimeter (DMM)
• Oscilloscope
• Twisted pair wires
• Signal generator
• Power resistor(s)
• Linear regulated power supply
• Filter components
• EVM or other complete audio circuit
Figure 49 shows the block diagrams of basic measurement systems for class-AB and class-D amplifiers. A sine
wave is normally used as the input signal since it consists of the fundamental frequency only (no other harmonics
are present). An analyzer is then connected to the APA output to measure the voltage output. The analyzer must
be capable of measuring the entire audio bandwidth. A regulated dc power supply is used to reduce the noise
and distortion injected into the APA through the power pins. A System Two audio measurement system (AP-II)
(Reference 1) by Audio Precision includes the signal generator and analyzer in one package.
The generator output and amplifier input must be ac-coupled. However, the EVMs already have the ac-coupling
capacitors, (C
IN
), so no additional coupling is required. The generator output impedance should be low to avoid
attenuating the test signal, and is important since the input resistance of APAs is not very high (about 10 kΩ).
Conversely the analyzer-input impedance should be high. The output impedance, R
OUT
, of the APA is normally in
the hundreds of milliohms and can be ignored for all but the power-related calculations.
Figure 49(a) shows a class-AB amplifier system. They take an analog signal input and produce an analog signal
output. These amplifier circuits can be directly connected to the AP-II or other analyzer input.
This is not true of the class-D amplifier system shown in Figure 49(b), which requires low pass filters in most
cases in order to measure the audio output waveforms. This is because it takes an analog input signal and
converts it into a pulse-width modulated (PWM) output signal that is not accurately processed by some
analyzers.
Copyright © 2003–2011, Texas Instruments Incorporated Submit Documentation Feedback 35
Product Folder Link(s): TPA3004D2