Datasheet
0 V
–12 V
+12 V
Current
OUTP
OUTN
Differential
Voltage
Across
Load
0 V
–12 V
+12 V
Current
OUTP
OUTN
Differential
Voltage
Across
Load
Output = 0 V
Output > 0 V
TPA3001D1
SLOS398E –DECEMBER 2002–REVISED AUGUST 2010
www.ti.com
Figure 32. The TPA3001D1 Output Voltage and Current Waveforms Into an Inductive Load
MAXIMUM ALLOWABLE OUTPUT POWER (SAFE OPERATING AREA)
The TPA3001D1 can drive load impedances as low as 3.6 Ω from power supply voltages ranging from 8 V to
18 V. To prevent device failure, however, the output power of the TPA3001D1 must be limited. Figure 33 shows
the maximum allowable output power versus load impedance for three power-supply voltages at an ambient
temperature of 25°C. (For ambient temperatures of 45°C and 60°C, see Figure 3 and Figure 4.)
16 Submit Documentation Feedback Copyright © 2002–2010, Texas Instruments Incorporated
Product Folder Link(s): TPA3001D1