Datasheet

1.2 TPA2016D2EVM Specifications
2 Operation
2.1 Quick Start List for Stand-Alone Operation
2.1.1 Software Installation Sequence
2.1.2 Evaluation Module Preparations
Operation
www.ti.com
V
DD
Supply voltage range –0.3 V to 6 V
I
DD
Supply current 2 A Maximum
P
o
Continuous output power per channel, 8 , Vdd = 5.0 V, THD + N = 10% 1.7 W
V
I
Audio Input Voltage 0.5 V to V
DD
- 0.5 V
RL Minimum load impedance 8
The TPA2016D2EVM can be evaluated in a stand-alone mode or when connected to existing circuits with
I
2
C controls.
A desktop or laptop computer with Windows™ XP installed is required in the stand-alone operation. Install
the software before connecting the EVM to a computer with a USB cable. The inputs accept standard
RCA plugs and the outputs accept banana connectors.
1. Insert the CD provided.
2. Unzip the files to a temporary folder.
3. Install TPA2016D2 software by executing setup.exe located in TPA2016D2 Interface\Volume.
Accept license agreement and defaults, and complete the installation. Note: you can uninstall later with
Add/Remove Programs.
Note: It is unnecessary to repeat the steps in Section 2.1.1 , once the software is installed.
1. Ensure that all external power sources are set to OFF.
2. Install shunt in jumper JP4;
3. Install shunts in jumpers JP5 and JP6 when single-ended audio inputs are used; this ties INL– and
INR– to ground.
4. Install shunts in JP2 and JP3 as shown in Figure 1 . This sets the TPA2016D2 to accept I
2
C inputs
from the EVM itself.
Figure 1. Place Shunts Horizontally Across SCL and SDA
2 TPA2016D2EVM SLOU201 June 2008
Submit Documentation Feedback