Datasheet
TEST SET-UP FOR GRAPHS (per channel)
TPA2012D2
IN+
IN-
OUT+
OUT-
V
DD
GND
C
I
C
I
R
I
R
I
Measurement
Output
+
-
1 Fm
+
-
Load
30kHz
Filter
LowPass
Measurement
Input
+
-
V
DD
TPA2012D2
SLOS438D – DECEMBER 2004 – REVISED JUNE 2008 ..................................................................................................................................................
www.ti.com
(1) C
I
was Shorted for any Common-Mode input voltage measurement.
(2) A 33- µ H inductor was placed in series with the load resistor to emulate a small speaker for efficiency measurements.
(3) The 30 – kHz low – pass filter is required even if the analyzer has an internal low – pass filter. An RC low pass filter (100
Ω , 47 nF) is used on each output for the data sheet graphs.
6 Submit Documentation Feedback Copyright © 2004 – 2008, Texas Instruments Incorporated
Product Folder Link(s): TPA2012D2