Quick Start List for Stand-Alone
2-6
Operation
Evaluation Module Preparations
6) Jumpers S2 and S3 select the least significant bits of the EVM I
2
C
address.
See section 2.5.3 for details
.
7) To allow the module SE/BTL control input to switch the amplifier IC
between single ended (SE) and bridge-tied load (BTL) output modes, set
output mode jumper S4 to
OFF
. To keep the module amplifier IC in the
single-ended output mode regardless of the control input state, set jumper
S4 to
ON
.
Table 2–4. Typical TPA0172 EVM Jumper Settings
EVM S2 S3 S4
TPA0172 OFF ON ON
Note: ON = Shunt installed, OFF = Open
8) When the module powers up or comes out of shutdown, the gain is set at
the –85 dB level. Gain settings can be adjusted through an I
2
C interface,
connecting to the EVM via connector P1 or through test
point terminals
TP3, TP4, TP5, and TP6 (Table 2–5). To ensure a common ground path,
connect a ground wire between a ground point on the I
2
C transmitting
device and GND on the EVM.
See section 2.5.3 for details.
Table 2–5. TPA0172 EVM Gain Control
CONNECTOR P1 TEST POINT TERMINAL FUNCTION
Pin 1 TP6 SDA input
Pin 10 TP3 SCL output
Pin 14 TP5 SCL input
Pin 15 TP4 SDA output
Control Inputs
9) Connect control lines to the various module control input pins as needed:
a) SE/BTL
: A high selects the single-ended (SE) output mode; a low or
float selects the bridge-tied load (BTL) output mode.
b) SHUTDOWN: A low shuts down the amplifier IC on the module; a high
or float allows normal operation.
Power-up
10) Verify correct voltage and input polarity and set the external power supply
to
ON.
The EVM should begin operation.
11) Adjust the signal source level as needed.