Datasheet

Transmission Characteristics (Continued)
Unless otherwise noted, limits printed in BOLD characters are guaranteed for V
CC
ea
5.0V
g
5%, V
BB
eb
5.0V
g
5%; T
A
e
0
§
Cto70
§
C by correlation with 100% electrical testing at T
A
e
25
§
C. All other limits are assured by correlation with other
production tests and/or product design and characterization. GNDA
e
0V, f
e
1.02 kHz, V
IN
e
0 dbm0, transmit input amplifier
connected for unity gain non-inverting. Typicals specified at V
CC
ea
5.0V, V
BB
eb
5.0V, T
A
e
25
§
C.
Symbol Parameter Conditions Min Typ Max Units
DISTORTION
STD
X,
Signal to Total Distortion Sinusoidal Test Method (Note 3)
STD
R
Transmit or Receive Level
e
3.0 dBm0 33 dBC
Half-Channel
e
0 dBm0 to
b
30 dBm0 36 dBC
eb
40 dBm0 XMT 29 dBC
RCV 30 dBC
eb
55 dBm0 XMT 14 dBC
RCV 15 dBC
SFD
X
Single Frequency Distortion,
b
46 dB
Transmit
SFD
R
Single Frequency Distortion,
b
46 dB
Receive
IMD Intermodulation Distortion Loop Around Measurement,
b
41 dB
VF
X
I
a
eb
4 dBm0 to
b
21 dBm0, Two
Frequencies in the Range
300 Hz
b
3400 Hz
CROSSTALK
CT
X-R
Transmit to Receive Crosstalk f
e
300 Hz
b
3000 Hz
D
R
e
Quiet PCM Code
b
90
b
75 dB
CT
R-X
Receive to Transmit Crosstalk f
e
300 Hz
b
3000 Hz, VF
X
I
e
0V
b
90
b
70 dB
(Note 2)
POWER AMPLIFIERS
V
O
PA Maximum 0 dBm0 Level Balanced Load, R
L
Connected Between
(Better than
g
0.1 dB Linearity over VPO
a
and VPO
b
.
the Range
b
10 dBm0 to
a
3 dBm0) R
L
e
600X 3.3 Vrms
R
L
e
1200X 3.5 Vrms
S/D
P
Signal/Distortion R
L
e
600X 50 dB
Note 1: Measured by extrapolation from the distortion test result at
b
50 dBm0.
Note 2: PPSR
X
, NPSR
X
, and CT
R
b
X
are measured with a
b
50 dBm0 activation signal applied to VF
X
I
a
.
Note 3: TP3064 is measured using C message weighted filter. TP3067 is measured using psophometric weighted filter.
12