PARAMETER MEASUREMENT INFORMATION
ethernet timing of clock signals
NO. PARAMETER MIN TYP MAX UNIT
300 CLKPHS Pulse duration of TXC 45 ns
301 CLKPER Cycle time of TXC 95 1000 ns
TXC
300
2.4 V
0.45 V
300
301
Figure 21. Ethernet Timing Of Clock Signals
ethernet timing of XMIT signals
NO. PARAMETER MIN TYP MAX UNIT
305 t
XDHLD
Hold time of TXD after TXC high 5 ns
306 t
XDVLD
Delay time from TXC high to TXD valid and
Delay time from TXC high to TXEN high
40 ns
TXC
TXD
TXEN
305
306
306
2.4 V
0.45 V
2.4 V
0.45 V
Figure 22. Ethernet Timing of XMIT Signals