Datasheet

 
 
SPRS161K − MARCH 2001 − REVISED JULY 2007
72
POST OFFICE BOX 1443 HOUSTON, TEXAS 77251−1443
capture timing
timing requirements (see Figure 35)
MIN MAX UNIT
t
w(CAP)
Pulse duration, CAP1 input low/high
if bit 6 of SCSR2 = 0
6t
c(CO)
ns
t
w(CAP)
Pulse duration, CAP1 input low/high
if bit 6 of SCSR2 = 1
12t
c(CO)
ns
CAP1
t
w(CAP)
CLKOUT
Figure 35. Capture Input Timing