Datasheet

TMS320F28069, TMS320F28068, TMS320F28067, TMS320F28066
TMS320F28065, TMS320F28064, TMS320F28063, TMS320F28062
www.ti.com
SPRS698D NOVEMBER 2010REVISED DECEMBER 2012
Table 5-56. eCAP Control and Status Registers
EALLOW
NAME eCAP1 eCAP2 eCAP3 SIZE (x16) DESCRIPTION
PROTECTED
TSCTR 0x6A00 0x6A20 0x6A40 2 No Time-Stamp Counter
CTRPHS 0x6A02 0x6A22 0x6A42 2 No Counter Phase Offset Value Register
CAP1 0x6A04 0x6A24 0x6A44 2 No Capture 1 Register
CAP2 0x6A06 0x6A26 0x6A46 2 No Capture 2 Register
CAP3 0x6A08 0x6A28 0x6A48 2 No Capture 3 Register
CAP4 0x6A0A 0x6A2A 0x6A4A 2 No Capture 4 Register
Reserved 0x6A0C – 0x6A2C – 0x6A4C – 8 No Reserved
0x6A12 0x6A32 0x6A52
ECCTL1 0x6A14 0x6A34 0x6A54 1 No Capture Control Register 1
ECCTL2 0x6A15 0x6A35 0x6A55 1 No Capture Control Register 2
ECEINT 0x6A16 0x6A36 0x6A56 1 No Capture Interrupt Enable Register
ECFLG 0x6A17 0x6A37 0x6A57 1 No Capture Interrupt Flag Register
ECCLR 0x6A18 0x6A38 0x6A58 1 No Capture Interrupt Clear Register
ECFRC 0x6A19 0x6A39 0x6A59 1 No Capture Interrupt Force Register
Reserved 0x6A1A – 0x6A3A – 0x6A5A – 6 No Reserved
0x6A1F 0x6A3F 0x6A5F
5.19.1 Enhanced Capture (eCAP) Electrical Data/Timing
Table 5-57 shows the eCAP timing requirement and Table 5-58 shows the eCAP switching characteristics.
Table 5-57. Enhanced Capture (eCAP) Timing Requirement
(1)
MIN MAX UNIT
t
w(CAP)
Capture input pulse width Asynchronous 2t
c(SCO)
cycles
Synchronous 2t
c(SCO)
cycles
With input qualifier 1t
c(SCO)
+ t
w(IQSW)
cycles
(1) For an explanation of the input qualifier parameters, see Table 5-69.
Table 5-58. eCAP Switching Characteristics
over recommended operating conditions (unless otherwise noted)
PARAMETER MIN MAX UNIT
t
w(APWM)
Pulse duration, APWMx output high/low 20 ns
Copyright © 2010–2012, Texas Instruments Incorporated Peripheral and Electrical Specifications 135
Submit Documentation Feedback
Product Folder Links: TMS320F28069 TMS320F28068 TMS320F28067 TMS320F28066 TMS320F28065
TMS320F28064 TMS320F28063 TMS320F28062