Video Port/VCXO Interpolated Control (VIC) Port User's Guide

www.ti.com
YFIFO
CbFIFO
VDOUT[9−2]
VCLKOUT
63 5655 4847 4039 32
Y5 Y4Y7 Y6
Y69 Y68Y71 Y70
Y77 Y76
Cb37 Cb36Cb38
Little-Endian Packing
VDOUT[19−12]
31 2423 1615 8 7 0
Y1 Y0Y3 Y2
Y65 Y64Y67 Y66
Y73 Y72Y75 Y74
31 2423 1615 8 7 0
Cb33 Cb32Cb35 Cb34
63 5655 4847 4039 32
IPCOUNT =IMGSIZE(78)
Cb5 Cb4Cb7 Cb6 Cb1 Cb0Cb3 Cb2
Cr FIFO
Cr 37 Cr36Cr38
31 2423 1615 8 7 0
Cr33 Cr32Cr35 Cr34
63 5655 4847 4039 32
Cr5 Cr4Cr7 Cr6 Cr1 Cr0Cr3 Cr2
Linen
Linen
Linen+1
Linen
Linen+1
Linen
Linen+1
4.9 Display Timing Examples
4.9.1 Interlaced BT.656 Timing Example
Display Timing Examples
Figure 4-24. Display Line Boundary Example
The following are examples of display output for several modes of operation.
This section shows an example of BT.656 display output for a 704 x 408 interlaced output image as might
be generated by MPEG decoding.
The horizontal output timing is shown in Figure 4-25 . This diagram assumes that there is a two VCLK
pipeline delay between the internal counter changing and the output on external pins. The actual delay
can be longer or shorter as long as it is consistent within any display mode. The BT.656 active line is
720-pixels wide. Figure 4-25 shows the 704-pixel image window centered in the screen that results in an
IMGHOFF x of 8 pixels.
The HBLNK and HSYNC signals are shown as they would be output for active-low operation. Note that
only one of the two signals is actually available externally. The HBLNK inactive edge occurs either on
sample 856 coincident with the start of SAV or on sample 0 (after SAV) if the HBDLA bit is set. For true
BT.656 operation, neither HBLNK nor HSYNC would be used.
The IPCOUNT operation follows the description in Section 4.1.2 . IPCOUNT resets to 0 at the first
displayed pixel (FPCOUNT = IMGHOFF x) and stops counting at the last displayed pixel (IPCOUNT =
IMGHSIZE x). The operation during non-display time is not a requirement, it could continue counting until
the next FPCOUNT = IMGHOFF x point or it could reset immediately after IMGHSIZE x or when FPCOUNT
is reset.
VDOUT shows the output data and switching between EAV, Blanking Data, SAV, Default Data, and FIFO
Data. It is assumed that the DVEN bit in VDCTL is set to enable the default output.
110 Video Display Port SPRUEM1 May 2007
Submit Documentation Feedback