Table 53. MAC Control Register (MACCONTROL) Field Descriptions (continued)
Bit Field Value Description
3 RXBUFFERFLOWEN Receive buffer flow control enable bit
0 Receive flow control is disabled. Half-duplex mode: no flow control generated collisions are
sent. Full-duplex mode: no outgoing pause frames are sent.
1 Receive flow control is enabled. Half-duplex mode: collisions are initiated when receive buffer
flow control is triggered. Full-duplex mode: outgoing pause frames are sent when receive flow
control is triggered.
2 Reserved 0 Reserved
1 LOOPBACK Loopback mode. The loopback mode forces internal full-duplex mode regardless of the
FULLDUPLEX bit. The loopback bit should be changed only when GMIIEN bit is deasserted.
0 Loopback mode is disabled.
1 Loopback mode is enabled.
0 FULLDUPLEX Full duplex mode.
0 Half-duplex mode is enabled.
1 Full-duplex mode is enabled.