Interpolated Control (VIC) Port Reference Guide

VIC Port Registers
VCXO Interpolated Control Port6-8 SPRU629
6.5.2 VIC Input Register (VICIN)
The DSP writes the input bits for VCXO interpolated control in the VIC input
register (VICIN). The DSP decides how often to update VICIN. The DSP can
write to VICIN only when the GO bit in the VIC control register (VICCTL) is set
to 1. The VIC module uses the MSBs of VICIN for precision values less than
16. The VICIN is shown in Figure 64 and described in Table 65.
Figure 64. VIC Input Register (VICIN)
31 16
Reserved
R-0
15 0
VICINBITS
R/W-0
Legend: R = Read only; R/W = Read/Write; -n = value after reset
Table 65. VIC Input Register (VICIN) Field Descriptions
Bit Field symval
Value Description
3116 Reserved 0 Reserved. The reserved bit location is always read as 0. A
value written to this field has no effect.
150 VICINBITS OF(value) 0FFFFh The DSP writes the input bits for VCXO interpolated control
to the VIC input bits.
For CSL implementation, use the notation VIC_VICIN_VICINBITS_symval