Interpolated Control (VIC) Port Reference Guide

Video Capture Registers
Video Capture Port3-52 SPRU629
Table 314. Video Capture Channel x Status Register (VCxSTAT)
Field Descriptions (Continued)
Bit
Description
Valuesymval
field
Bit
TSI ModeRaw Data ModeBT.656 or Y/C Mode
Valuesymval
field
2716 VCYPOS OF(value) 0FFFh Current VCOUNT
value and the line
that is currently being
received (within the
current field).
Upper 12 bits of
the data counter.
Upper 12 bits of
the data counter.
1513 Reserved 0 Reserved. The reserved bit location is always read as 0. A
value written to this field has no effect.
12 VCFLD VCFLD bit indicates which field is currently being captured.
The VCFLD bit is updated based on the field detection logic
selected by the FLDD bit in VCACTL.
NONE 0 Field 1 is active. Not used. Not used.
DETECTED 1 Field 2 is active. Not used. Not used.
110 VCXPOS OF(value) 0FFFh Current HCOUNT
value. The pixel
index of the last
received pixel.
Lower 12 bits of
the data counter.
Lower 12 bits of
the data counter.
For CSL implementation, use the notation VP_VCxSTAT_field_symval