Datasheet
"#$%
SBOS371A − AUGUST 2006 − REVISED OCTOBER 2007
www.ti.com
2
ABSOLUTE MAXIMUM RATINGS
(1)
Power Supply, V
S
7.0V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Input Voltage
(2)
−0.5V to V
S
+ 0.5V. . . . . . . . . . . . . . . . . . . . . . . . . .
Input Current 10mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating Temperature Range −55°C to +127°C. . . . . . . . . . . . . . .
Storage Temperature Range −60°C to +130°C. . . . . . . . . . . . . . . . .
Junction Temperature (T
J
max) +150°C. . . . . . . . . . . . . . . . . . . . . .
ESD Rating:
Human Body Model (HBM) 4000V. . . . . . . . . . . . . . . . . . . . . . .
Charged Device Model (CDM) 1000V. . . . . . . . . . . . . . . . . . . .
(1)
Stresses above these ratings may cause permanent damage.
Exposure to absolute maximum conditions for extended periods
may degrade device reliability. These are stress ratings only, and
functional operation of the device at these or any other conditions
beyond those specified is not supported.
(2)
Input voltage rating applies to all TMP401 input voltages.
This integrated circuit can be damaged by ESD. Texas
Instruments recommends that all integrated circuits be
handled with appropriate precautions. Failure to observe
proper handling and installation procedures can cause damage.
ESD damage can range from subtle performance degradation to
complete device failure. Precision integrated circuits may be more
susceptible to damage because very small parametric changes could
cause the device not to meet its published specifications.
PACKAGE/ORDERING INFORMATION
(1)
PRODUCT DESCRIPTION ADDRESS PACKAGE-LEAD
PACKAGE
DESIGNATOR
PACKAGE
MARKING
TMP401 Remote Junction Temperature Sensor 1001100 MSOP-8 DGK BRB
(1)
For the most current package and ordering information, see the Package Option Addendum at the end of this document, or see the TI website
at www.ti.com.
PIN CONFIGURATION
TOP VIEW MSOP-8
1
2
3
4
8
7
6
5
SCL
SDA
ALERT/THERM2
GND
V+
D+
D
−
THERM
TMP401
PIN ASSIGNMENTS
PIN NAME DESCRIPTION
1 V+ Positive supply (3V to 5.5V)
2 D+
Positive connection to remote
temperature sensor
3 D−
Negative connection to remote
temperature sensor
4 THERM
Thermal flag, active low, open-drain;
requires pull-up resistor to V+
5 GND Ground
6 ALERT/THERM2
Alert (reconfigurable as second
thermal flag), active low, open-drain;
requires pull-up resistor to V+
7 SDA
Serial data line for SMBus, open-drain;
requires pull-up resistor to V+
8 SCL
Serial clock line for SMBus,
open-drain; requires pull-up resistor to
V+