Datasheet
F28M36P63C, F28M36P53C, F28M36H53C, F28M36H53B, F28M36H33C, F28M36H33B
www.ti.com
SPRS825C –OCTOBER 2012–REVISED FEBRUARY 2014
Table 6-1. Current Consumption at 150-MHz C28x SYSCLKOUT and 75-MHz M3SSCLK (continued)
VREG ENABLED VREG DISABLED
MODE TEST CONDITIONS
(1)
I
DDIO
(2)
I
DDA
I
DD18
I
DD12
I
DDIO
(2)
I
DDA
TYP MAX TYP MAX TYP MAX TYP MAX TYP MAX TYP MAX
• PLL is on.
• Cortex-M3 CPU is not
executing.
• M3SSCLK is on.
SLEEP IDLE – 145 mA – 2 mA – 20 mA – 110 mA – 10 mA – 2 mA
• C28CLKIN is on.
• C28x CPU is not executing.
• C28CPUCLK is off.
• C28SYSCLK is on.
• PLL is on.
• Cortex-M3 CPU is not
executing.
• M3SSCLK is on.
SLEEP
– 125 mA – 2 mA – 20 mA – 90 mA – 10 mA – 2 mA
STANDBY
• C28CLKIN is off.
• C28x CPU is not executing.
• C28CPUCLK is off.
• C28SYSCLK is off.
• PLL is off.
• Cortex-M3 CPU is not
executing.
• M3SSCLK is 32 kHz.
DEEP SLEEP
– 75 mA – 2 mA – 5 mA – 60 mA – 6 mA – 2 mA
STANDBY
• C28CLKIN is off.
• C28x CPU is not executing.
• C28CPUCLK is off.
• C28SYSCLK is off.
Copyright © 2012–2014, Texas Instruments Incorporated Electrical Specifications 127
Submit Documentation Feedback
Product Folder Links: F28M36P63C F28M36P53C F28M36H53C F28M36H53B F28M36H33C F28M36H33B