Datasheet

TLV809J25, TLV809L30
TLV809K33, TLV809I50
SLVSA03C JUNE 2010REVISED FEBRUARY 2012
www.ti.com
This integrated circuit can be damaged by ESD. Texas Instruments recommends that all integrated circuits be handled with
appropriate precautions. Failure to observe proper handling and installation procedures can cause damage.
ESD damage can range from subtle performance degradation to complete device failure. Precision integrated circuits may be more
susceptible to damage because very small parametric changes could cause the device not to meet its published specifications.
PACKAGE/ORDERING INFORMATION
(1)
SPECIFIED
THRESHOLD PACKAGE- PACKAGE OPERATING PACKAGE ORDERING TRANSPORT MEDIA,
PRODUCT VOLTAGE LEAD DESIGNATOR TEMPERATURE MARKING INFORMATION QUANTITY
TLV809J25DBVR Tape and Reel, 3000
DBV –40°C to +85°C VTCI
TLV809J25DBVT Tape and Reel, 250
TLV809J25 2.25 V SOT23-3
TLV809J25DBZR Tape and Reel, 3000
DBZ –40°C to +85°C BCMT
TLV809J25DBZT Tape and Reel, 250
TLV809L30DBVR Tape and Reel, 3000
DBV –40°C to +85°C VTXI
TLV809L30DBVT Tape and Reel, 250
TLV809L30 2.64 V SOT23-3
TLV809L30DBZR Tape and Reel, 3000
DBZ –40°C to +85°C BCMZ
TLV809L30DBZT Tape and Reel, 250
TLV809K33DBVR Tape and Reel, 3000
DBV –40°C to +85°C VTRI
TLV809K33DBVT Tape and Reel, 250
TLV809K33 2.93 V SOT23-3
TLV809K33DBZR Tape and Reel, 3000
DBZ –40°C to +85°C BCMX
TLV809K33DBZT Tape and Reel, 250
TLV809I50DBVR Tape and Reel, 3000
DBV –40°C to +85°C VTBI
TLV809I50DBVT Tape and Reel, 250
TLV809I50 4.55 V SOT23-3
TLV809I50DBZR Tape and Reel, 3000
DBZ –40°C to +85°C BCMV
TLV809I50DBZT Tape and Reel, 250
(1) For the most current package and ordering information, see the Package Option Addendum at the end of this data sheet, or visit the
device product folder at www.ti.com.
ABSOLUTE MAXIMUM RATINGS
(1)
Over operating free-air temperature range (unless otherwise noted) .
VALUE UNIT
V
DD
Supply voltage
(2)
7 V
All other pins
(2)
–0.3 to 7 V
I
OL
Maximum low output current 5 mA
I
OH
Maximum high output current –5 mA
I
IK
Input clamp current (V
I
< 0 or V
I
> V
DD
) ±20 mA
I
OK
Output clamp current (V
O
< 0 or V
O
> V
DD
) ±20 mA
T
A
Operating free-air temperature range –40 to +85 °C
T
stg
Storage temperature range –65 to +150 °C
Soldering temperature +260 °C
(1) Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating
Conditions is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) All voltage values are with respect to GND. For reliable operation the device should not be operated at 7 V for more than t = 1000h
continuously
2 Submit Documentation Feedback Copyright © 2010–2012, Texas Instruments Incorporated
Product Folder Link(s): TLV809J25 TLV809L30 TLV809K33 TLV809I50