Datasheet
www.ti.com
Switching Characteristics
Switching Characteristics
TLV7256
DUAL COMPARATOR
SLCS147A – OCTOBER 2006 – REVISED JANUARY 2007
V
CC+
= 5 V, V
CC–
= GND, T
A
= 25 ° C (unless otherwise noted)
PARAMETER TEST CONDITIONS TYP UNIT
Overdrive = 100 mV 680
t
PLH
Propagation delay time (turn on) ns
TTL step input 500
Overdrive = 100 mV 250
t
PHL
Propagation delay time (turn off) ns
TTL step input 380
t
TLH
60
Response time Overdrive = 100 mV ns
t
THL
8
V
CC+
= 3 V, V
CC–
= GND, T
A
= 25 ° C (unless otherwise noted)
PARAMETER TEST CONDITIONS TYP UNIT
t
PLH
Propagation delay time (turn on) Overdrive = 100 mV 550 ns
t
PHL
Propagation delay time (turn off) Overdrive = 100 mV 250 ns
t
TLH
30
Response time Overdrive = 100 mV ns
t
THL
8
6
Submit Documentation Feedback