Datasheet
TLV61220
SLVSB53 –MAY 2012
www.ti.com
These devices have limited built-in ESD protection. The leads should be shorted together or the device placed in conductive foam
during storage or handling to prevent electrostatic damage to the MOS gates.
AVAILABLE DEVICE OPTIONS
OUTPUT VOLTAGE
T
A
PACKAGE PART NUMBER
DC/DC
–40°C to 85°C Adjustable 6-Pin SOT-23 TLV61220DBV
ABSOLUTE MAXIMUM RATINGS
over operating free-air temperature range (unless otherwise noted)
(1)
MIN MAX UNIT
V
IN
Input voltage range on VBAT, SW, VOUT, EN, FB – 0.3 to 7.5 V
T
J
Operating junction temperature range –40 150 °C
T
stg
Storage temperature range –65 150 °C
Human Body Model (HBM)
(2)
2 kV
ESD
Charged Device Model (CDM)
(2)
1.5 kV
(1) Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating
Conditions is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) ESD testing is performed according to the respective JESD22 JEDEC standard.
DISSIPATION RATINGS TABLE
THERMAL THERMAL THERMAL DERATING FACTOR
POWER RATING
PACKAGE RESISTANCE RESISTANCE RESISTANCE ABOVE
T
A
≤ 25°C
Θ
JA
(1)
Θ
JB
Θ
JC
T
A
= 25°C
DBV 130 °C/W 27 °C/W 41 °C/W 769 mW 7.7 mW/°C
(1) Thermal ratings are determined assuming a high K PCB design according to JEDEC standard JESD51-7.
RECOMMENDED OPERATING CONDITIONS
MIN NOM MAX UNIT
V
IN
Supply voltage at VIN 0.7 5.5 V
T
A
Operating free air temperature range –40 85 °C
T
J
Operating virtual junction temperature range –40 125 °C
2 Submit Documentation Feedback Copyright © 2012, Texas Instruments Incorporated
Product Folder Link(s): TLV61220