ABSOLUTE MAXIMUM RATINGS
RECOMMENDED OPERATING CONDITIONS
TLV5639C
TLV5639I
SLAS189C MARCH 1999 REVISED JANUARY 2004
over operating free-air temperature range (unless otherwise noted)
(1)
UNIT
Supply voltage (V
DD
to AGND) 7 V
Reference input voltage range - 0.3 V to V
DD
+ 0.3 V
Digital input voltage range - 0.3 V to V
DD
+ 0.3 V
Operating free-air temperature range, T
A
TLV5639C 0°C to 70°C
TLV5639I -40°C to 85°C
Storage temperature range, T
stg
-65°C to 150°C
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds 260°C
(1) Stresses beyond those listed under absolute maximum ratings may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under recommended operating
conditions is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
MIN NOM MAX UNIT
V
DD
= 5 V 4.5 5 5.5 V
Supply voltage, V
DD
V
DD
= 3 V 2.7 3 3.3 V
Power on threshold voltage, POR 0.55 2 V
V
DD
= 2.7 V 2
High-level digital input voltage, V
IH
V
V
DD
= 5.5 V 2.4
V
DD
= 2.7 V 0.6
Low-level digital input voltage, V
IL
V
V
DD
= 5.5 V 1
Reference voltage, V
ref
to REF terminal V
DD
= 5 V
(1)
AGND 2.048 V
DD
-1.5 V
Reference voltage, V
ref
to REF terminal V
DD
= 3 V
(1)
AGND 1.024 V
DD
-1.5 V
Load resistance, R
L
2 k
Load capacitance, C
L
100 pF
TLV5639C 0 70
Operating free-air temperature, T
A
°C
TLV5639I 40 85
(1) Due to the x2 output buffer, a reference input voltage V
DD/2
causes clipping of the transfer function. The output buffer of the internal
reference must be disabled, if an external reference is used.
3