Datasheet
www.ti.com
ELECTRICAL CHARACTERISTICS
TIMING REQUIREMENTS
TLV5636
SLAS223C – JUNE 1999 – REVISED APRIL 2004
over recommended operating free-air temperature range, supply voltages, and reference voltages (unless otherwise noted)
ANALOG OUTPUT DYNAMIC PERFORMANCE
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
Fast 1 3
R
L
= 10 k Ω ,
t
s(FS)
Output settling time (full scale) C
L
= 100 pF, µs
see note
(1)
Slow 3.5 7
Fast 0.5 1.5
R
L
= 10 k Ω ,
t
s(CC)
Output settling time, code to code C
L
= 100 pF, µs
see note
(2)
Slow 1 2
Fast 8
R
L
= 10 k Ω ,
SR Slew rate C
L
= 100 pF, V/µs
see note
(3)
Slow 1.5
DIN = 0 to 1, f
out
= 1 kHz,
Glitch energy 5 nV-s
CS = V
DD
SNR Signal-to-noise ratio 71 75
S/(N+D) Signal-to-noise + distortion 59 66
f
s
= 480 kSPS, f
out
= 1 kHz,
dB
R
L
= 10 k Ω , C
L
= 100 pF
THD Total harmonic distortion -67 -59
Spurious free dynamic range 59 69
(1) Settling time is the time for the output signal to remain within +0.5 LSB of the final measured value for a digital input code change of
0x20 to 0xFDF and 0xFDF to 0x020 respectively. Assured by design; not tested.
(2) Settling time is the time for the output signal to remain within +0.5 LSB of the final measured value for a digital input code change of one
count. Assured by design; not tested.
(3) Slew rate determines the time it takes for a change of the DAC output from 10% to 90% full-scale voltage.
DIGITAL INPUTS
MIN NOM MAX UNIT
t
su(CS-FS)
Setup time, CS low before FS falling edge 10 ns
t
su(FS-CK)
Setup time, FS low before first negative SCLK edge 8 ns
Setup time, 16
th
negative edge after FS low on which bit D0 is sampled before
t
su(C16-FS)
10 ns
rising edge of FS.
Setup time, 16
th
positive SCLK edge (first positive after D0 is sampled) before CS
t
su(C16-CS)
rising edge. If FS is used instead of 16
th
positive edge to update DAC, then setup 10 ns
time between FS rising edge and CS rising edge.
t
wH
SCLK pulse duration high 25 ns
t
wL
SCLK pulse duration low 25 ns
t
su(D)
Setup time, data ready before SCLK falling edge 8 ns
t
h(D)
Hold time, data held valid after SCLK falling edge 5 ns
t
wH(FS)
FS duration high 25 ns
5