Datasheet

www.ti.com
ABSOLUTE MAXIMUM RATINGS
RECOMMENDED OPERATING CONDITIONS
TLV5633C
TLV5633I
SLAS190C MARCH 1999 REVISED SEPTEMBER 2006
over operating free-air temperature range (unless otherwise noted)
(1)
UNIT
Supply voltage (DV
DD
, AV
DD
to AGND) 7 V
Supply voltage difference range, AV
DD
- DV
DD
-2.8 V to 2.8 V
Reference input voltage range -0.3 V to V
DD
+ 0.3 V
Digital input voltage range -0.3 V to V
DD
+ 0.3 V
TLV5633C 0°C to 70°C
Operating free-air temperature range, T
A
TLV5633I -40°C to 85°C
Storage temperature range, T
stg
-65°C to 150°C
(1) Stresses beyond those listed under "absolute maximum ratings" may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under "recommended operating
conditions" is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
MIN NOM MAX UNIT
5-V operation 4.5 5 5.5 V
Supply voltage, DV
DD
, AV
DD
3-V operation 2.7 3 3.3 V
Supply voltage difference, V
DD
= AV
DD
- DV
DD
0 0 0 V
Power on reset voltage, POR 0.55 2 V
DV
DD
= 2.7 V 2
High-level digital input voltage, V
IH
V
DV
DD
= 5.5 V 2.4
DV
DD
= 2.7 V 0.6
Low-level digital input voltage, V
IL
V
DV
DD
= 5.5 V 1
Reference voltage, V
ref
to REF terminal (5-V supply)
(1)
AGND 2.048 AV
DD
-1.5 V
Reference voltage, V
ref
to REF terminal (3-V supply)
(1)
AGND 1.024 AV
DD
-1.5 V
Load resistance, R
L
2 k
Load capacitance, C
L
100 pF
TLV5633C 0 70
Operating free-air temperature, T
A
°C
TLV5633I -40 85
(1) Due to the x2 output buffer, a reference input voltage AV
DD/2
causes clipping of the transfer function. The output buffer of the internal
reference must be disabled, if an external reference is used.
3