Datasheet
TLV5626
2.7-V TO 5.5-V LOW-POWER DUAL 8-BIT DIGITAL-TO-ANALOG
CONVERTER WITH INTERNAL REFERENCE AND POWER DOWN
SLAS236A –JUNE 1999 – REVISED JUNE 2000
3
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
†
Supply voltage (V
DD
to AGND) 7 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Reference input voltage range – 0.3 V to V
DD
+ 0.3 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Digital input voltage range – 0.3 V to V
DD
+ 0.3 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating free-air temperature range, T
A
: TLV5626C 0°C to 70°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TLV5626I –40°C to 85°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage temperature range, T
stg
–65°C to 150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds 260°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
†
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
recommended operating conditions
MIN NOM MAX UNIT
Su
pp
ly voltage V
DD
V
DD
= 5 V 4.5 5 5.5 V
S
u
ppl
y v
oltage
,
V
DD
V
DD
= 3 V 2.7 3 3.3 V
Power on threshold voltage, POR 0.55 2 V
High-level digital input voltage, V
IH
V
DD
= 2.7 V to 5.5 V 2 V
Low-level digital input voltage, V
IL
V
DD
= 2.7 V to 5.5 V 0.8 V
Reference voltage, V
ref
to REF terminal V
DD
= 5 V (see Note 1) AGND 2.048 V
DD
–1.5 V
Reference voltage, V
ref
to REF terminal V
DD
= 3 V (see Note 1) AGND 1.024 V
DD
–1.5 V
Load resistance, R
L
2 kΩ
Load capacitance, C
L
100 pF
Clock frequency, f
CLK
20 MHz
O
p
erating free air tem
p
erature T
A
TLV5626C 0 70
°
C
Operating
free
-
air
temperat
u
re
,
T
A
TLV5626I –40 85
°C
NOTE 1: Due to the x2 output buffer, a reference input voltage ≥ (V
DD
– 0.4 V)/2 causes clipping of the transfer function. The output buffer of the
internal reference must be disabled, if an external reference is used.