Datasheet

www.ti.com
ABSOLUTE MAXIMUM RATINGS
RECOMMENDED OPERATING CONDITIONS
TLV5619
SLAS172F DECEMBER 1997 REVISED FEBRUARY 2004
over operating free-air temperature range (unless otherwise noted)
(1)
UNIT
Supply voltage (V
DD
to GND) 7 V
Analog input voltage range - 0.3 V to V
DD
+ 0.3 V
Reference input voltage V
DD
+ 0.3 V
Digital input voltage range to GND - 0.3 V to V
DD
+ 0.3 V
Operating free-air temperature range, T
A
TLV5619C 0°C to 70°C
TLV5619I -40°C to 85°C
TLV5619Q -40°C to 125°C
Storage temperature range, T
stg
-65°C to 150°C
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds 260°C
(1) Stresses beyond those listed under, , absolute maximum ratings” may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under, , recommended operating
conditions” is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
MIN NOM MAX UNIT
Supply voltage, V
DD
(5-V Supply) 4.5 5 5.5 V
Supply voltage, V
DD
(3-V Supply) 2.7 3 3.3 V
DV
DD
= 2.7 V 2
High-level digital input voltage, V
IH
V
DV
DD
= 5.5 V 2.4
DV
DD
= 2.7 V 0.6
V
Low-level digital input voltage, V
IL
TLV5619C and TLV5619I 1
DV
DD
= 5.5 V
TLV5619Q 0.8
Reference voltage, V
ref
to REFIN terminal (5-V Supply) 0 2.048 V
DD
-1.5 V
Reference voltage, V
ref
to REFIN terminal (3-V Supply) 0 1.024 V
DD
-1.5 V
Load resistance, R
L
2 10 k
Load capacitance, C
L
100 pF
TLV5619C 0 70
Operating free-air temperature, T
A
TLV5619I 40 85 °C
TLV5619Q 40 125
3