Datasheet

TLV5618A
2.7-V TO 5.5-V LOW-POWER DUAL 12-BIT
DIGITAL-TO-ANALOG CONVERTER WITH POWER DOWN
SLAS230H JULY 1999 REVISED JULY 2002
3
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage (V
DD
to AGND) 7 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Reference input voltage range 0.3 V to V
DD
+ 0.3 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Digital input voltage range 0.3 V to V
DD
+ 0.3 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating free-air temperature range, T
A
: TLV5618AC 0°C to 70°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TLV5618AI 40°C to 85°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TLV5618AQ 40°C to 125°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TLV5618AM 55°C to 125°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage temperature range, T
stg
65°C to 150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds 260°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Stresses beyond those listed under absolute maximum ratings may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under recommended operating conditions is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
DISSIPATION RATING TABLE
PACKAGE
T
A
25°C DERATING FACTOR T
A
= 70°C T
A
= 85°C T
A
= 125°C
PACKAGE
T
A
25 C
POWER RATING
DERATING
FACTOR
ABOVE T
A
= 25°C
T
A
=
70 C
POWER RATING
T
A
=
85 C
POWER RATING
T
A
=
125 C
POWER RATING
D 635 mW 5.08 mW/°C 407 mW 330 mW 127 mW
FK 1375 mW 11.00 mW/°C 880 mW 715 mW 275 mW
JG 1050 mW 8.40 mW/°C 672 mW 546 mW 210 mW
This is the inverse of the traditional junction-to-ambient thermal resistance (RΘ
JA
). Thermal resistances are not production tested and are for
informational purposes only.
recommended operating conditions
MIN NOM MAX UNIT
Supply voltage V
V
DD
= 5 V 4.5 5 5.5
Supply voltage, V
DD
V
DD
= 3 V 2.7 3 3.3
V
Power on reset 0.55 2 V
High level digital input voltage V
V
DD
= 2.7 V 2
High-level digital input voltage, V
IH
V
DD
= 5.5 V 2.4
V
Low level digital input voltage V
V
DD
= 2.7 V 0.6
Low-level digital input voltage, V
IL
V
DD
= 5.5 V 1
V
Reference voltage V to REF terminal
V
DD
= 5 V (see Note 1) AGND 2.048 V
DD
1.5
Reference voltage, V
ref
to REF terminal
V
DD
= 3 V (see Note 1) AGND 1.024 V
DD
1.5
V
Load resistance, R
L
2 k
Load capacitance, C
L
100 pF
Clock frequency, f
(CLK)
20 MHz
TLV5618AC 0 70
O
p
erating free air tem
p
erature T
A
TLV5618AI 40 85
Operating free-air temperature, T
A
TLV5618AQ 40 125
°C
TLV5618AM 55 125
NOTE 1: Due to the x2 output buffer, a reference input voltage (V
DD
0.4 V)/2 causes clipping of the transfer function.