Datasheet
TLV5614
2.7-V TO 5.5-V 12-BIT 3-µS QUADRUPLE DIGITAL-TO-ANALOG CONVERTERS
WITH POWER DOWN
SLAS188B – SEPTEMBER 1998 – REVISED APRIL 2003
3
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
Terminal Functions
TERMINAL
I/O
DESCRIPTION
NAME NO.
I/O
DESCRIPTION
AGND 9 Analog ground
AV
DD
16 Analog supply
CS 6 I Chip select. This terminal is active low.
DGND 8 Digital ground
DIN 4 I Serial data input
DV
DD
1 Digital supply
FS
7 I Frame sync input. The falling edge of the frame sync pulse indicates the start of a serial data frame shifted out to
the TLV5614.
PD
2 I Power down pin. Powers down all DACs (overriding their individual power down settings), and all output stages.
This terminal is active low.
LDAC
3 I Load DAC. When the LDAC signal is high, no DAC output updates occur when the input digital data is read into
the serial interface. The DAC outputs are only updated when LDAC
is low.
REFINAB 15 I Voltage reference input for DACs A and B.
REFINCD 10 I Voltage reference input for DACs C and D.
SCLK 5 I Serial clock input
OUTA 14 O DACA output
OUTB 13 O DACB output
OUTC 12 O DACC output
OUTD 11 O DACD output
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
†
Supply voltage, (DV
DD
, AV
DD
to GND) 7 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Supply voltage difference, (AV
DD
to DV
DD
) –2.8 V to 2.8 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Digital input voltage range –0.3 V to DV
DD
+ 0.3 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Reference input voltage range –0.3 V to AV
DD
+ 0.3 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating free-air temperature range, T
A
: TLV5614C 0°C to 70°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TLV5614I –40°C to 85°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage temperature range, T
stg
–65°C to 150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds 260°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
†
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.