Datasheet


     
  
SLOS310B − DECEMBER 2000 − REVISED SEPTEMBER 2006
8
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
TYPICAL CHARACTERISTICS
Figure 15
2.40
2.45
2.50
2.55
0 102030405060708090
−0.10
−0.05
0
0.05
0.10
t − Time − µs
INVERTING SMALL-SIGNAL PULSE RESPONSE
vs
TIME
− Output Voltage − VV
O
V
DD
= 5 V
R
L
= 100
C
L
= 50 pF
A
V
= −1
T
A
= 25°C
− Input Voltage − VV
I
V
O−
V
I
V
O+
Figure 16
−1.0
−0.5
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
−40 −15 10 35 60 85
T
A
− Free-Air Temperature − °C
V
DD
= 5 V
V
DD
= 2.7 V
V
IN
= Bypass Voltage (V
DD
/2)
1 µF Cap on Bypass
A
V
= 1
R
L
= Open
Shutdown = V
DD
SHUTDOWN SUPPLY CURRENT
vs
FREE-AIR TEMPERATURE
DD(SD)
I Shutdown Supply Current −
Aµ
Figure 17
0
1
2
3
0
200 400 600 800
1000 1200
0
2
4
t − Time − µs
SHUTDOWN MODE PULSE RESPONSE
vs
TIME
− Output Voltage − VV
O
V
DD
= 5 V
R
L
= 100
C
L
= 10 pF
A
V
= 1
V
I
= V
DD/2
T
A
= 25°C
V
O+
and V
O
SD in
SD − Shutdown Pulse − V
6
−1
Figure 18
−0.1
0.0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
V
DD
− Supply Voltage − V
SHUTDOWN SUPPLY CURRENT
vs
SUPPLY VOLTAGE
T
A
= 85°C
T
A
= 25°C
T
A
= −40°C
DD(SD)
I Shutdown Supply Current −
0 1 2 3.5 4.5 5 5.5432.51.50.5
Aµ