Datasheet

TLV320DAC32
www.ti.com
........................................................................................................................................ SLAS506B NOVEMBER 2006 REVISED DECEMBER 2008
Page 0 / Register 95: Output Driver Short Circuit Detection Status Register
BIT READ/ RESET DESCRIPTION
WRITE VALUE
D7 R 0 HPLOUT Short Circuit Detection Status
0: No short circuit detected at HPLOUT
1: Short circuit detected at HPLOUT
D6 R 0 HPROUT Short Circuit Detection Status
0: No short circuit detected at HPROUT
1: Short circuit detected at HPROUT
D5 R 0 HPLCOM Short Circuit Detection Status
0: No short circuit detected at HPLCOM
1: Short circuit detected at HPLCOM
D4 R 0 HPRCOM Short Circuit Detection Status
0: No short circuit detected at HPRCOM
1: Short circuit detected at HPRCOM
D3 R 0 HPLCOM Power Status
0: HPLCOM is not fully powered up
1: HPLCOM is fully powered up
D2 R 0 HPRCOM Power Status
0: HPRCOM is not fully powered up
1: HPRCOM is fully powered up
D1-D0 R 00 Reserved. Do not write to these register bits.
Page 0 / Register 96: Sticky Interrupt Flags Register
BIT READ/ RESET DESCRIPTION
WRITE VALUE
D7 R 0 HPLOUT Short Circuit Detection Status
0: No short circuit detected at HPLOUT driver
1: Short circuit detected at HPLOUT driver
D6 R 0 HPROUT Short Circuit Detection Status
0: No short circuit detected at HPROUT driver
1: Short circuit detected at HPROUT driver
D5 R 0 HPLCOM Short Circuit Detection Status
0: No short circuit detected at HPLCOM driver
1: Short circuit detected at HPLCOM driver
D4 R 0 HPRCOM Short Circuit Detection Status
0: No short circuit detected at HPRCOM driver
1: Short circuit detected at HPRCOM driver
D3 R 0 Button Press Detection Status
0: No Headset Button Press detected
1: Headset Button Pressed
D2 R 0 Headset Detection Status
0: No Headset insertion/removal is detected
1: Headset insertion/removal is detected
D1-D0 R 00 Reserved. Do not write to these bits.
Page 0 / Register 97: Real-time Interrupt Flags Register
BIT READ/ RESET DESCRIPTION
WRITE VALUE
D7 R 0 HPLOUT Short Circuit Detection Status
0: No short circuit detected at HPLOUT driver
1: Short circuit detected at HPLOUT driver
D6 R 0 HPROUT Short Circuit Detection Status
0: No short circuit detected at HPROUT driver
1: Short circuit detected at HPROUT driver
D5 R 0 HPLCOM Short Circuit Detection Status
0: No short circuit detected at HPLCOM driver
1: Short circuit detected at HPLCOM driver
Copyright © 2006 2008, Texas Instruments Incorporated Submit Documentation Feedback 53
Product Folder Link(s): TLV320DAC32