Datasheet

T0145-11
WCLK
BCLK
DIN
t (WS)
h
t (BCLK)
H
t (DI)
S
t (BCLK)
L
t (DI)
h
t (WS)
S
t
r
t
f
TLV320DAC3100
SLAS671A FEBRUARY 2010REVISED MAY 2012
www.ti.com
3.4.2 I
2
S/LJF/RJF Timing in Slave Mode
All specifications at 25°C, DVDD = 1.8 V
Note: All timing specifications are measured at characterization.
IOVDD = 1.1 V IOVDD = 3.3 V
PARAMETER UNIT
MIN MAX MIN MAX
t
H
(BCLK) BCLK high period 35 35 ns
t
L
(BCLK) BCLK low period 35 35 ns
t
s
(WS) WCLK setup 8 6 ns
t
h
(WS) WCLK hold 8 6 ns
t
s
(DI) DIN setup 8 6 ns
t
h
(DI) DIN hold 8 6 ns
t
r
Rise time 4 4 ns
t
f
Fall time 4 4 ns
Figure 3-2. I
2
S/LJF/RJF Timing in Slave Mode
8 ELECTRICAL SPECIFICATIONS Copyright © 2010–2012, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Link(s): TLV320DAC3100