Datasheet

Play- Paused
DACPowerDown
Update
DigitalFilter
Coefficients
DACPowerUP
Wait20ms
VolumeRampDown
SoftMute
Restore Previous
VolumeLevel(Ramp)
in(B)ms
Play- Continue
Wait(A)ms
Forf =32kHz
S
® Wait25ms(min)
Forf =48kHz Wait20ms(min)
S
®
For =32kHz ®f 25ms
Forf =48kHz 20ms
S
S
®
DACVolumeRampDownWAIT Time(A)
DACVolumeRampUp Time(B)
F0024-02
TLV320DAC3100
www.ti.com
SLAS671A FEBRUARY 2010REVISED MAY 2012
Figure 5-19. Example Flow for Updating DAC Digital Filter Coefficients During Play
5.5.10 Digital Mixing and Routing
The TLV320DAC3101 has four digital mixing blocks. Each mixer can provide either mixing or multiplexing
of the digital audio data. This arrangement of digital mixers allows independent volume control for both the
playback data and the key-click sound. The first set of mixers can be used to make monaural signals from
left and right audio data, or they can even be used to swap channels to the DAC. This function is
accomplished by selecting left audio data for the right DAC input, and right data for the left DAC input. The
second set of mixers provides mixing of the audio data stream and the key-click sound. The digital routing
can be configured by writing to page 0 / register 63, bits D5–D4 for the left channel and bits D3–D2 for the
right channel.
Because the key-click function uses the digital signal-processing block, the CODEC_CLKIN, DAC, analog
volume control, and output driver must be powered on for the key-click sound to occur.
Copyright © 2010–2012, Texas Instruments Incorporated APPLICATION INFORMATION 39
Submit Documentation Feedback
Product Folder Link(s): TLV320DAC3100