Datasheet
3−9
3.3.2.2 Normal-Mode Sampling Rates
In Normal mode, the following DAC sampling rates, depending on the MCLK frequency, are available:
MCLK = 12.288 MHz
SAMPLING RATE
FILTER
SAMPLING-RATE CONTROL SETTINGS
FILTER
TYPE
SAMPLING-RATE CONTROL SETTINGS
kHz
FILTER
TYPE
SR3 SR2 SR1 SR0 BOSR CLKIN
96 2 0 1 1 1 0 0
48 1 0 0 0 0 0 0
32 1 0 1 1 0 0 0
8 1 0 0 1 1 0 0
48 2 0 1 1 1 0 1
24 1 0 0 0 0 0 1
16 1 0 1 1 0 0 1
4 1 0 0 1 1 0 1
MCLK = 11.2896 MHz
SAMPLING RATE
FILTER
SAMPLING-RATE CONTROL SETTINGS
FILTER
TYPE
SAMPLING-RATE CONTROL SETTINGS
kHz
FILTER
TYPE
SR3 SR2 SR1 SR0 BOSR CLKIN
88.2 2 1 1 1 1 0 0
44.1 1 1 0 0 0 0 0
8.021 1 1 0 1 1 0 0
44.1 2 1 1 1 1 0 1
22.05 1 1 0 0 0 0 1
4.0105 1 1 0 1 0 0 1
MCLK = 18.432 MHz
SAMPLING RATE
FILTER
SAMPLING-RATE CONTROL SETTINGS
FILTER
TYPE
SAMPLING-RATE CONTROL SETTINGS
kHz
FILTER
TYPE
SR3 SR2 SR1 SR0 BOSR CLKIN
96 2 0 1 1 1 1 0
48 1 0 0 0 0 1 0
32 1 0 1 1 0 1 0
8 1 0 0 1 1 1 0
48 2 0 1 1 1 1 1
24 1 0 0 0 0 1 1
16 1 0 1 1 0 1 1
4 1 0 0 1 1 1 1
MCLK = 16.9344 MHz
SAMPLING RATE
FILTER
SAMPLING-RATE CONTROL SETTINGS
FILTER
TYPE
SAMPLING-RATE CONTROL SETTINGS
kHz
FILTER
TYPE
SR3 SR2 SR1 SR0 BOSR CLKIN
88.2 2 1 1 1 1 1 0
44.1 1 1 0 0 0 1 0
8.021 1 1 0 1 1 1 0
44.1 2 1 1 1 1 1 1
22.05 1 1 0 0 0 1 1
4.0105 1 1 0 1 1 1 1