AIC3212 Control Software
3.2.4 Register Inspector Table
Figure 8. Register Inspector Window
The contents of TLV320AIC3212 register map can be accessed through the Register inspector table. The
“Page” number control selects the page to be displayed in the register table. The register table contains
information such as register name, current register value and the bit field of the current register value.
While using the register inspect table, user should first specify the page number. Once the page is
specified, user can inspect or change the register value by either entering the hex value of the register or
changing the corresponding bits for that register.
11
SLAU435March 2012 TLV320AIC3212EVM-U Evaluation Module
Submit Documentation Feedback
Copyright © 2012, Texas Instruments Incorporated