Page 0 / Register 93 (0x5D): AGC Gain-Applied Reading
READ/ RESET
BIT DESCRIPTION
WRITE VALUE
D7–D0 R XXXX XXXX 1110 1000: Gain applied by AGC = –12 dB
1110 1001: Gain applied by AGC = –11.5 dB
...
0000 0000: Gain applied by AGC = 0 dB
...
0111 0011: Gain applied by AGC = 57.5 dB
0111 0100: Gain applied by AGC = 58 dB
0111 0101: Gain applied by AGC = 58.5 dB
0111 0110: Gain applied by AGC = 59 dB
0111 0111: Gain applied by AGC = 59.5 dB
Page 0 / Registers 94–101: Reserved
READ/ RESET
BIT DESCRIPTION
WRITE VALUE
D7–D0 R/W XXXX XXXX Reserved. Do not write to these registers.
Page 0 / Register 102 (0x66): ADC DC Measurement 1
READ/ RESET
BIT DESCRIPTION
WRITE VALUE
D7 R/W 0 0: DC measurement is Disabled for mono ADC channel
1: DC measurment is Enabled for mono ADC channel
D6 R/W 0 Reserved. Write only reset value.
D5 R/W 0 0: DC measurement is done based on first-order sinc filter with averaging of 2
D
.
1: DC measurment is done based on first-order low-pass IIR filter whose coefficients are calculated
based on D value.
D4–D0 R/W 0 0000 DC Meaurement D setting:
00000: Reserved. Don't use.
00001: D = 1
00010: D = 2
...
10011: D = 19
10100: D = 20
10101 to 11111: Reserved. Don't use.
Page 0 / Register 103 (0x67): ADC DC Measurement 2
READ/ RESET
BIT DESCRIPTION
WRITE VALUE
D7 R/W 0 Reserved. Write only reset value.
D6 R/W 0 0: DC measurement data update is enabled.
1: DC measurment data update is disabled. User can read the last updated data without any data
corruption.
D5 R/W 0 0: For IIR-based dc measurement, the measurment value is the instantaneous output of the IIR filter
1: For IIR-based dc measurement, the measurment value is update before periodic clearing of the IIR
filter
D4–D0 R/W 0 0000 IIR-Based DC Measurment, Average Time Setting:
00000: Infinite average is used
00001: Averaging time is 2
1
ADC modulator clock periods
00010: Averaging time is 2
2
ADC modulator clock periods
...
10011: Averaging time is 2
19
ADC modulator clock periods
10100: Averaging time is 2
20
ADC modulator clock periods
10101 to 11111: Reserved. Don't use.
Page 0 / Register 104 (0x67): ADC DC Measurement Output 1
READ/ RESET
BIT DESCRIPTION
WRITE VALUE
D7–D0 R 0000 0000 ADC DC Measurement Output (23:16)