Datasheet
TLV320AIC3106
SLAS509E – DECEMBER 2006 – REVISED DECEMBER 2008 ........................................................................................................................................
www.ti.com
Page 0 / Register 93: RIGHT_LOP/M Output Level Control Register
READ/ RESET
BIT DESCRIPTION
WRITE VALUE
D7 – D4 R/W 0000 RIGHT_LOP/M Output Level Control
0000: Output level control = 0 dB
0001: Output level control = 1 dB
0010: Output level control = 2 dB
...
1000: Output level control = 8 dB
1001: Output level control = 9 dB
1010 – 1111: Reserved. Do not write these sequences to these register bits.
D3 R/W 0 RIGHT_LOP/M Mute
0: RIGHT_LOP/M is muted
1: RIGHT_LOP/M is not muted
D2 R 0 Reserved. Don ’ t write to this register bit.
D1 R 1 RIGHT_LOP/M Volume Control Status
0: All programmed gains to RIGHT_LOP/M have been applied
1: Not all programmed gains to RIGHT_LOP/M have been applied yet
D0 R 0 RIGHT_LOP/M Power Status
0: RIGHT_LOP/M is not fully powered up
1: RIGHT_LOP/M is fully powered up
Page 0 / Register 94: Module Power Status Register
READ/ RESET
BIT DESCRIPTION
WRITE VALUE
D7 R 0 Left DAC Power Status
0: Left DAC not fully powered up
1: Left DAC fully powered up
D6 R 0 Right DAC Power Status
0: Right DAC not fully powered up
1: Right DAC fully powered up
D5 R 0 MONO_LOP/M Power Status
0: MONO_LOP/M output driver powered down
1: MONO_LOP/M output driver powered up
D4 R 0 LEFT_LOP/M Power Status
0: LEFT_LOP/M output driver powered down
1: LEFT_LOP/M output driver powered up
D3 R 0 RIGHT_LOP/M Power Status
0: RIGHT_LOP/M is not fully powered up
1: RIGHT_LOP/M is fully powered up
D2 R 0 HPLOUT Driver Power Status
0: HPLOUT Driver is not fully powered up
1: HPLOUT Driver is fully powered up
D1 R 0 HPROUT Driver Power Status
0: HPROUT Driver is not fully powered up
1: HPROUT Driver is fully powered up
D0 R 0 Reserved. Do not write to this register bit.
76 Submit Documentation Feedback Copyright © 2006 – 2008, Texas Instruments Incorporated
Product Folder Link(s): TLV320AIC3106