Table 71. Page 0/Register 105: Right-AGC New Programmable Attack Time Register
BIT READ/ RESET DESCRIPTION
WRITE VALUE
D7 R/W 0 Attack Time Register Selection
0: Attack time for the right AGC is generated from page 0, register 29.
1: Attack time for the right AGC is generated from this register.
D6–D5 R/W 00 Baseline AGC attack time
00: Right-AGC attack time = 7 ms
01: Right-AGC attack time = 8 ms
10: Right-AGC attack time = 10 ms
11: Right-AGC attack time = 11 ms
D4–D2 R/W 000 Multiplication Factor for Baseline AGC
000: Multiplication factor for the baseline AGC attack time = 1
001: Multiplication factor for the baseline AGC attack time = 2
010: Multiplication factor for the baseline AGC attack time = 4
011: Multiplication factor for the baseline AGC attack time = 8
100: Multiplication factor for the baseline AGC attack time = 16
101: Multiplication factor for the baseline AGC attack time = 32
110: Multiplication factor for the baseline AGC attack time = 64
111: Multiplication factor for the baseline AGC attack time = 128
D1–D0 R/W 00 Reserved. Write only zeros to these bits.
Table 72. Page 0/Register 106: Right-AGC New Programmable Decay Time Register
(1)
BIT READ/ RESET DESCRIPTION
WRITE VALUE
D7 R/W 0 Decay Time Register Selection
0: Decay time for the right AGC is generated from page 0, register 29.
1: Decay time for the right AGC is generated from this register.
D6–D5 R/W 00 Baseline AGC Decay Time
00: Right-AGC decay time = 50 ms
01: Right-AGC decay time = 150 ms
10: Right-AGC decay time = 250 ms
11: Right-AGC decay time = 350 ms
D4–D2 R/W 000 Multiplication Factor for Baseline AGC
000: Multiplication factor for the baseline AGC decay time = 1
001: Multiplication factor for the baseline AGC decay time = 2
010: Multiplication factor for the baseline AGC decay time = 4
011: Multiplication factor for the baseline AGC decay time = 8
100: Multiplication factor for the baseline AGC decay time = 16
101: Multiplication factor for the baseline AGC decay time = 32
110: Multiplication factor for the baseline AGC decay time = 64
111: Multiplication factor for the baseline AGC decay time = 128
D1–D0 R/W 00 Reserved. Write only zeros to these bits.
(1) Decay time is limited based on NCODEC ratio that is selected. For
NCODEC = 1, Maximum decay time = 4 seconds
NCODEC = 1.5, Maximum decay time = 5.6 seconds
NCODEC = 2, Maximum decay time = 8 seconds
NCODEC = 2.5, Maximum decay time = 9.6 seconds
NCODEC = 3 or 3.5, Maximum decay time = 11.2 seconds
NCODEC = 4 or 4.5, Maximum decay time = 16 seconds
NCODEC = 5, Maximum decay time = 19.2 seconds
NCODEC = 5.5 or 6, Maximum decay time = 22.4 seconds