Datasheet
Table Of Contents
- FEATURES
- APPLICATIONS
- DESCRIPTION
- DESCRIPTION (Continued)
- PIN ASSIGNMENTS
- ABSOLUTE MAXIMUM RATINGS
- PACKAGE THERMAL RATINGS
- SYSTEM THERMAL CHARACTERISTICS
- RECOMMENDED OPERATING CONDITIONS
- ELECTRICAL CHARACTERISTICS
- TYPICAL CHARACTERISTICS
- OVERVIEW
- HARDWARE RESET
- DIGITAL CONTROL SERIAL INTERFACE
- I2C CONTROL INTERFACE
- I2C BUS DEBUG IN A GLITCHED SYSTEM
- DIGITAL AUDIO DATA SERIAL INTERFACE
- RIGHT-JUSTIFIED MODE
- LEFT-JUSTIFIED MODE
- I2S MODE
- DSP MODE
- TDM DATA TRANSFER
- AUDIO DATA CONVERTERS
- AUDIO CLOCK GENERATION
- STEREO AUDIO ADC
- DIGITAL AUDIO PROCESSING FOR RECORD PATH
- AUTOMATIC GAIN CONTROL (AGC)
- STEREO AUDIO DAC
- DIGITAL AUDIO PROCESSING FOR PLAYBACK
- DIGITAL INTERPOLATION FILTER
- DELTA-SIGMA AUDIO DAC
- AUDIO DAC DIGITAL VOLUME CONTROL
- INCREASING DAC DYNAMIC RANGE
- ANALOG OUTPUT COMMON-MODE ADJUSTMENT
- AUDIO DAC POWER CONTROL
- AUDIO ANALOG INPUTS
- ANALOG INPUT BYPASS PATH FUNCTIONALITY
- ADC PGA SIGNAL BYPASS PATH FUNCTIONALITY
- INPUT IMPEDANCE AND VCM CONTROL
- MICBIAS GENERATION
- PASSIVE ANALOG BYPASS DURING POWER DOWN
- ANALOG FULLY DIFFERENTIAL LINE OUTPUT DRIVERS
- ANALOG HIGH-POWER OUTPUT DRIVERS
- SHORT-CIRCUIT OUTPUT PROTECTION
- JACK/HEADSET DETECTION
- CONTROL REGISTERS
- Output Stage Volume Controls

Output Stage Volume Controls
TLV320AIC3101
SLAS520D – FEBRUARY 2007 – REVISED DECEMBER 2008 ........................................................................................................................................
www.ti.com
A basic analog volume control with range from 0 dB to – 78 dB and mute is replicated multiple times in the output
stage network, connected to each of the analog signals that route to the output stage. In addition, to enable
completely independent mixing operations to be performed for each output driver, each analog signal coming into
the output stage may have up to seven separate volume controls. These volume controls all have approximately
0.5-dB step programmability over most of the gain range, with steps increasing slightly at the lowest attenuations.
Table 6 lists the detailed gain versus programmed setting for this basic volume control.
Table 6. Output Stage Volume Control Settings and Gains
Gain Setting Analog Gain Gain Setting Analog Gain Gain Setting Analog Gain Gain Setting Analog Gain
(dB) (dB) (dB) (dB)
0 0 0 – 45.2 – 30.1 – 15 90 60 30
1 – 0.5 31 – 15.5 61 – 30.6 91 – 45.8
2 – 1 32 – 16 62 – 31.1 92 – 46.2
3 – 1.5 33 – 16.5 63 – 31.6 93 – 46.7
4 – 2 34 – 17 64 – 32.1 94 – 47.4
5 – 2.5 35 – 17.5 65 – 32.6 95 – 47.9
6 – 3 36 – 18 66 – 33.1 96 – 48.2
7 – 3.5 37 – 18.6 67 – 33.6 97 – 48.7
8 – 4 38 – 19.1 68 – 34.1 98 – 49.3
9 – 4.5 39 – 19.6 69 – 34.6 99 – 50
10 – 5 40 – 20.1 70 – 35.1 100 – 50.3
11 – 5.5 41 – 20.6 71 – 35.7 101 – 51
12 – 6 42 – 21.1 72 – 36.1 102 – 51.4
13 – 6.5 43 – 21.6 73 – 36.7 103 – 51.8
14 – 7 44 – 22.1 74 – 37.1 104 – 52.2
15 – 7.5 45 – 22.6 75 – 37.7 105 – 52.7
16 – 8 46 – 23.1 76 – 38.2 106 – 53.7
17 – 8.5 47 – 23.6 77 – 38.7 107 – 54.2
18 – 9 48 – 24.1 78 – 39.2 108 – 55.3
19 – 9.5 49 – 24.6 79 – 39.7 109 – 56.7
20 – 10 50 – 25.1 80 – 40.2 110 – 58.3
21 – 10.5 51 – 25.6 81 – 40.7 111 – 60.2
22 – 11 52 – 26.1 82 – 41.2 112 – 62.7
23 – 11.5 53 – 26.6 83 – 41.7 113 – 64.3
24 – 12 54 – 27.1 84 – 42.2 114 – 66.2
25 – 12.5 55 – 27.6 85 – 42.7 115 – 68.7
26 – 13 56 – 28.1 86 – 43.2 116 – 72.2
27 – 13.5 57 – 28.6 87 – 43.8 117 – 78.3
28 – 14 58 – 29.1 88 – 44.3 118 – 127 Mute
29 – 14.5 59 – 29.6 89 – 44.8
Page 0/Register 45: Reserved Register
BIT READ/ RESET DESCRIPTION
WRITE VALUE
D7 – D0 R/W 0000 0000 Reserved. Do not write to this register.
64 Submit Documentation Feedback Copyright © 2007 – 2008, Texas Instruments Incorporated