Page 0 / Register 94: Module Power Status Register
BIT READ/ RESET DESCRIPTION
WRITE VALUE
D7 R 0 Left DAC Power Status
0: Left DAC not fully powered up
1: Left DAC fully powered up
D6 R 0 Right DAC Power Status
0: Right DAC not fully powered up
1: Right DAC fully powered up
D5 R 0 Reserved. Do not write to this register bit.
D4 R 0 LEFT_LOP Power Status
0: LEFT_LOP output driver powered down
1: LEFT_LOP output driver powered up
D3 R 0 RIGHT_LOP Power Status
0: RIGHT_LOP is not fully powered up
1: RIGHT_LOP is fully powered up
D2 R 0 HPLOUT Driver Power Status
0: HPLOUT Driver is not fully powered up
1: HPLOUT Driver is fully powered up
D1 R 0 HPROUT Driver Power Status
0: HPROUT Driver is not fully powered up
1: HPROUT Driver is fully powered up
D0 R 0 Reserved. Do not write to this register bit.
Page 0 / Register 95: Output Driver Short Circuit Detection Status Register
BIT READ/ RESET DESCRIPTION
WRITE VALUE
D7 R 0 HPLOUT Short Circuit Detection Status
0: No short circuit detected at HPLOUT
1: Short circuit detected at HPLOUT
D6 R 0 HPROUT Short Circuit Detection Status
0: No short circuit detected at HPROUT
1: Short circuit detected at HPROUT
D5 R 0 HPCOM Short Circuit Detection Status
0: No short circuit detected at HPCOM
1: Short circuit detected at HPCOM
D4 R 0 Reserved. Do not write to this register bit.
D3 R 0 HPCOM Power Status
0: HPCOM is not fully powered up
1: HPCOM is fully powered up
D2-D0 R 0 Reserved. Do not write to these register bits.