Datasheet
TLV320AIC3007
www.ti.com
..................................................................................................................................................................................................... SLOS619 – APRIL 2009
Page 0 / Register 65: HPROUT Output Level Control Register
BIT READ/ RESET DESCRIPTION
WRITE VALUE
D7-D4 R/W 0000 HPROUT Output Level Control
0000: Output level control = 0 dB
0001: Output level control = 1 dB
0010: Output level control = 2 dB
...
1000: Output level control = 8 dB
1001: Output level control = 9 dB
1010 – 1111: Reserved. Do not write these sequences to these register bits.
D3 R/W 0 HPROUT Mute
0: HPROUT is muted
1: HPROUT is not muted
D2 R/W 1 HPROUT Power Down Drive Control
0: HPROUT is weakly driven to a common-mode when powered down
1: HPROUT is 3-stated with powered down
D1 R 1 HPROUT Volume Control Status
0: All programmed gains to HPROUT have been applied
1: Not all programmed gains to HPROUT have been applied yet
D0 R/W 0 HPROUT Power Control
0: HPROUT is not fully powered up
1: HPROUT is fully powered up
Page 0 / Register 66: Reserved
BIT READ/ RESET DESCRIPTION
WRITE VALUE
D7 – D0 R 00000000 Reserved. Do not write to this register.
Page 0 / Register 67: Reserved
BIT READ/ RESET DESCRIPTION
WRITE VALUE
D7 – D0 R 00000000 Reserved. Do not write to this register.
Page 0 / Register 68: Reserved
BIT READ/ RESET DESCRIPTION
WRITE VALUE
D7 – D0 R 00000000 Reserved. Do not write to this register.
Page 0 / Register 69: Reserved
BIT READ/ RESET DESCRIPTION
WRITE VALUE
D7 – D0 R 00000000 Reserved. Do not write to this register.
Page 0 / Register 70: Reserved
BIT READ/ RESET DESCRIPTION
WRITE VALUE
D7 – D0 R 00000000 Reserved. Do not write to this register.
Page 0 / Register 71: Reserved
BIT READ/ RESET DESCRIPTION
WRITE VALUE
D7 – D R 00000000 Reserved. Do not write to this register.
0
Copyright © 2009, Texas Instruments Incorporated Submit Documentation Feedback 69