Datasheet
Table Of Contents
- Title Page - SLWS106H
- IMPORTANT NOTICE
- Contents
- List of Illustrations
- 1 Introduction
- 2 Specifications
- 2.1 Absolute Maximum Ratings Over Operating Free-Air Temperature Range (unless otherwise noted)†
- 2.2 Recommended Operating Conditions
- 2.3 Electrical Characteristics Over Recommended Operating Conditions, AVDD, HPVDD, BVDD = 3.3 V, DVDD = 1.5 V, Slave Mode, XTI/ MCLK = 256fs, fs = 48 kHz ( unless otherwise stated)
- 2.4 Digital-Interface Timing
- 3 How to Use the TLV320AIC23B
- Appendix A: Mechanical Data

3−10
3.3.2.2 Normal-Mode Sampling Rates
In normal mode, the following ADC and DAC sampling rates, depending on the MCLK frequency, are available:
MCLK = 12.288 MHz
SAMPLING RATE
SAMPLING-RATE CONTROL SETTINGS
ADC
DAC
FILTER TYPE
SAMPLING-RATE CONTROL SETTINGS
ADC
(kHz)
DAC
(kHz)
FILTER TYPE
SR3 SR2 SR1 SR0 BOSR
96 96 2 0 1 1 1 0
48 48 1 0 0 0 0 0
32 32 1 0 1 1 0 0
8 8 1 0 0 1 1 0
48 8 1 0 0 0 1 0
8 48 1 0 0 1 0 0
MCLK = 11.2896 MHz
SAMPLING RATE
SAMPLING-RATE CONTROL SETTINGS
ADC
DAC
FILTER TYPE
SAMPLING-RATE CONTROL SETTINGS
ADC
(kHz)
DAC
(kHz)
FILTER TYPE
SR3 SR2 SR1 SR0 BOSR
88.2 88.2 2 1 1 1 1 0
44.1 44.1 1 1 0 0 0 0
8.021 8.021 1 1 0 1 1 0
44.1 8.021 1 1 0 0 1 0
8.021 44.1 1 1 0 1 0 0
MCLK = 18.432 MHz
SAMPLING RATE
SAMPLING-RATE CONTROL SETTINGS
ADC
DAC
FILTER TYPE
SAMPLING-RATE CONTROL SETTINGS
ADC
(kHz)
DAC
(kHz)
FILTER TYPE
SR3 SR2 SR1 SR0 BOSR
96 96 2 0 1 1 1 1
48 48 1 0 0 0 0 1
32 32 1 0 1 1 0 1
8 8 1 0 0 1 1 1
48 8 1 0 0 0 1 1
8 48 1 0 0 1 0 1
MCLK = 16.9344 MHz
SAMPLING RATE
SAMPLING-RATE CONTROL SETTINGS
ADC
DAC
FILTER TYPE
SAMPLING-RATE CONTROL SETTINGS
ADC
(kHz)
DAC
(kHz)
FILTER TYPE
SR3 SR2 SR1 SR0 BOSR
88.2 88.2 2 1 1 1 1 1
44.1 44.1 1 1 0 0 0 1
8.021 8.021 1 1 0 1 1 1
44.1 8.021 1 1 0 0 1 1
8.021 44.1 1 1 0 1 0 1