Datasheet
www.ti.com
DAC DYNAMIC PERFORMANCE
TLV320AIC20, TLV320AIC21
TLV320AIC24, TLV320AIC25
TLV320AIC20K, TLV320AIC24K
SLAS363D – MARCH 2002 – REVISED APRIL 2005
AIC20/21/24/25 AIC20k/24k
PARAMETER TEST CONDITIONS
MIN TYP MAX MIN TYP MAX UNIT
The test condition is the digital equivalent of a 1020-Hz input signal with an 8-kHz conversion rate.
DAC Line Output (LINEO-, LINEO+)
The test is measured at output of the application schematic low-pass filter. The test is conducted in
Using FIR Filter
16-bit mode.
V
I
= 0 dB 88 92 80 92
SNR Signal-to-noise ratio
V
I
= -9 dB 81 83 83
V
I
= 0 dB 84 90 70 90
THD Total Harmonic Distortion dB
V
I
= -9 dB 77 84 84
V
I
= 0 dB 82 88 88
Signal-to-total Harmonic
THD+N
Distortion + noise
V
I
= -9 dB 76 80 80
The test condition is the digital equivalent of a 1020-Hz input signal with an 8-kHz conversion rate.
DAC Line Output (LINEO-, LINEO+)
The test is measured at output of the application schematic low-pass filter. The test is conducted in
Using IIR Filter
16-bit mode.
V
I
= 0 dB 83 83
SNR Signal-to-noise ratio
V
I
= -9 dB 74 74
V
I
= 0 dB 85 85
THD Total Harmonic Distortion dB
V
I
= -9 dB 80 80
V
I
= 0 dB 80 80
Signal-to-total Harmonic
THD+N
Distortion + noise
V
I
= -9 dB 73 73
The test condition is the digital equivalent of a 1020-Hz input signal with an 8-kHz conversion rate.
DAC Headphone Output (HDSO-,
The test is measured at output of the application schematic low-pass filter. The test is conducted in
HDSO+), (HNSO-, HNSO+)
(1)
16-bit mode.
V
I
= 0 dB 92 92
SNR Signal-to-noise ratio
V
I
= -9 dB 83 83
V
I
= 0 dB 90 90
THD Total Harmonic Distortion dB
V
I
= -9 dB 89 89
V
I
= 0 dB 88 88
Signal-to-total Harmonic
THD+N
Distortion + noise
V
I
= -9 dB 82 82
The test condition is the digital equivalent of a 1020-Hz input signal with an 8-kHz conversion rate.
DAC Speaker Output (SPKO-,
The test is measured at output of the application schematic low-pass filter. The test is conducted in
SPKO+)
(1) (2)
16-bit mode.
V
I
= 0 dB 91 91
SNR Signal-to-noise ratio
V
I
= -9 dB 83 83
V
I
= 0 dB 91 91
THD Total Harmonic Distortion dB
V
I
= -9 dB 91 91
V
I
= 0 dB 88 88
Signal-to-total Harmonic
THD+N
Distortion + noise
V
I
= -9 dB 82 82
(1) The conversion rate is 8 kHz.
(2) The speaker driver is valid only for the AIC20/21/20K.