Datasheet
www.ti.com
...
...
...
15 14 1 0 1415 1 0 1415 1 0
One SCLK
Data Frame Control Frame
Hi-Z
FS
Turbo SCLK
FS
DIN / DOUT
DIN / DOUT
Sampling Period
Data Frame Control Frame
Data Frame Control Frame Data Frame
Hi-Z
Stand-Alone Case:
Cascade Case (Master + 4 Slaves):
... ...
15 14
1 0 1415 1 0
One SCLK
Data Frame
Hi-Z
FS
DIN / DOUT
Data Frame
Stand-Alone Case:
Cascade Case (Master + 4 Slaves):
Turbo SCLK
FS
DIN / DOUT
Sampling Period
Data Frame
Hi-Z
Data Frame
TURBO PROGRAMMING MODE
TURBO CONTINUOUS DATA TRANSFER MODE
Sampling Period
Sampling Period
Control Frame
Hi-Z
...
1415 1 0
Hi-Z
Turbo SCLK
Turbo SCLK
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
Control Register Programming
TLV320AIC12, TLV320AIC13
TLV320AIC14, TLV320AIC15
TLV320AIC12K, TLV320AIC14K
SLWS115E – OCTOBER 2001 – REVISED JANUARY 2007
Figure 38. Turbo Programming Mode (SCLK Is Not Drawn To Scale)
The TLV320AIC1x contains six control registers that are used to program available modes of operation. All
register programming occurs during the control frame through DIN. New configuration takes effect after a delay
of one frame sync FS except the software reset, which happens after 6 MCLKs from the falling edge of the next
frame sync FS. The TLV320AIC1x is defaulted to the programming mode upon power up. Set bit 6 in control
register 1 to switch to continuous data transfer mode. If the 15+1 data format of DIN has been selected, the LSB
of the DIN to 1 to switch from continuous data transfer mode to programming set mode. Otherwise, either the
device needs to be reset or the host port writes 0 to bit D6 of control register 1 during the continuous data
transfer mode to switch back to the programming mode.
37
Submit Documentation Feedback