Datasheet

37
D0D13D15 D14 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1
SCLK
DCSI
Start Bit
= 0
Device
Address
Register
Address
Register Data Stop Bit
= 1
Figure 39. Direct Configuration Mode Timing
To program control register 1 of device 3, send data in with the following format through DCSI:
SB Device Address Register Address X Register Content
0 0 1 1 0 0 1 x x x x x x x x x
D15 D0
3.4 Continuous Data Transfer Mode
In continuous data transfer mode, the 16-bit converter data are transferred contiguously with no inactivity between
bits. This mode is available in the stand-alone master with M1M0 = 00 (FS-pulse mode) and selected by setting bit
D5 of control register 3 to 1. The secondary communication request is not allowed in this mode and therefore the direct
configuration mode should be used to program the internal control registers. The continuous data transfer mode is
designed to support the TI DSP McBSPs autobuffering unit (ABU) operation in which serial port interrupts are not
generated with each word transferred to prevent CPUs ISR overheads.
D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0
D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0
SCLK
FS
DIN
DOUT
E15 E13 E12
E15 E14 E13 E12
E14C0
C0
Figure 310. Continuous Data Transfer Mode Timing