A–3
A.3 Control Register 3
Table A–5. Control Register 3
D7 D6 D5 D4 D3 D2 D1 D0 DESCRIPTION
0 0 – – – – – – Default
0 1 – – – – – – Analog loopback enabled
1 0 – – – – – – Digital loopback enabled
1 1 – – – – – – Event-monitor mode enabled (write cycle only)
– – 1 – – – – – Continuous data-transfer mode (master only)
– – 0 – – – – – Default
– – – 1 – – – – FLAG output = D3
– – – 0 – – – – FLAG output = secondary communication flag
– – – F – – – FLAG value
– – – – – 0 0 – Default
– – – – – 0 1 – Disable ADC channel
– – – – – 1 0 – Disable DAC channel
– – – – – 1 1 – Software power-down mode
– – – – – – – 1 16-bit data format for ADC
– – – – – – – 0 Not 16-bit data format for ADC
Default value: 00000000