Datasheet
TLV320ADC3001
www.ti.com
SLAS548C –OCTOBER 2008– REVISED APRIL 2011
Page 0 / Register 94: Right AGC Control 1
READ/ RESET
BIT DESCRIPTION
WRITE VALUE
D7 R/W 0 0: Right AGC disabled
1: Right AGC enabled
D6–D4 R/W 000 000: Right AGC target level = –5.5 dB
000: Right AGC target level = –8 dB
001: Right AGC target level = –10 dB
010: Right AGC target level = –12 dB
011: Right AGC target level = –14 dB
100: Right AGC target level = –17 dB
101: Right AGC target level = –20 dB
111: Right AGC target level = –24 dB
D3–D0 R 0000 Reserved. Do not write any value other than reset value.
Page 0 / Register 95: Right AGC Control 2
READ/ RESET
BIT DESCRIPTION
WRITE VALUE
D7–D6 R/W 00 00: Right AGC hysteresis setting of 1 dB
01: Right AGC hysteresis setting of 2 dB
10: Right AGC hysteresis setting of 4 dB
11: Right AGC hysteresis disabled.
D5–D1 R/W 00 000 00 000: Right AGC noise/silence detection is disabled.
00 001: Right AGC noise threshold = –30 dB
00 010: Right AGC noise threshold = –32 dB
00 011: Right AGC noise threshold = –34 dB
...
11 101: Right AGC noise threshold = –86 dB
11 110: Right AGC noise threshold = –88 dB
11 111: Right AGC noise threshold = –90 dB
D0 R/W 0 0: Disable clip stepping for right AGC.
1: Enable clip stepping for right AGC.
Page 0 / Register 96: Right AGC Maximum Gain
READ/ RESET
BIT DESCRIPTION
WRITE VALUE
D7 R 0 Reserved. Do not write any value other than reset value.
D6–D0 R/W 111 1111 000 0000: Right AGC maximum gain = 0 dB
000 0001: Right AGC maximum gain = 0.5 dB
000 0010: Right AGC maximum gain = 1 dB
...
101 0000: Right AGC maximum gain = 40 dB
101 0001–111 1111: Not Used.
Page 0 / Register 97: Right AGC Attack Time
READ/ RESET
BIT DESCRIPTION
WRITE VALUE
D7–D3 R/W 0000 0 0000 0: Right AGC attack time = 1 × (32/f
S
)
0000 1: Right AGC attack time = 3 × (32/f
S
)
0001 0: Right AGC attack time = 5 × (32/f
S
)
0001 1: Right AGC attack time = 7 × (32/f
S
)
0010 0: Right AGC attack time = 9 × (32/f
S
)
...
1111 0: Right AGC attack time = 61 × (32/f
S
)
1111 1: Right AGC attack time = 63 × (32/f
S
)
D2–D0 R/W 000 000: Multiplication factor for the programmed right AGC attack time = 1
001: Multiplication factor for the programmed right AGC attack time = 2
010: Multiplication factor for the programmed right AGC attack time = 4
...
111: Multiplication factor for the programmed right AGC attack time = 128
Copyright © 2008–2011, Texas Instruments Incorporated 59