Datasheet
TLV3201
TLV3202
SBOS561A –MARCH 2012–REVISED JUNE 2012
www.ti.com
This integrated circuit can be damaged by ESD. Texas Instruments recommends that all integrated circuits be handled with
appropriate precautions. Failure to observe proper handling and installation procedures can cause damage.
ESD damage can range from subtle performance degradation to complete device failure. Precision integrated circuits may be more
susceptible to damage because very small parametric changes could cause the device not to meet its published specifications.
PACKAGE ORDERING INFORMATION
(1)
PACKAGE
PRODUCT PACKAGE-LEAD
(2)
DESIGNATOR PACKAGE MARKING ORDERING NUMBER
SOT23-5 DBV RAI TLV3201AIDBV
TLV3201
SC70-5 DCK SDP TLV3201AIDCK
SOIC-8 D TL3202 TLV3202AID
TLV3202
MSOP-8 DGK VUDC TLV3202AIDGK
(1) For the most current package and ordering information, see the Package Option Addendum at the end of this document, or visit the
device product folder at www.ti.com.
(2) Package drawings, standard packing quantities, thermal data, symbolization, and printed circuit board (PCB) design guidelines are
available at www.ti.com/sc/package.
ABSOLUTE MAXIMUM RATINGS
(1)
Over operating free-air temperature range, unless otherwise noted.
VALUE UNIT
Supply voltage 7 V
Voltage
(2)
–0.5 to (V
CC
) + 0.5 V
Signal input terminals
Current
(2)
±10 mA
Output short circuit
(3)
100 mA
Operating temperature range –55 to +125 °C
Storage temperature range, T
stg
–65 to +150 °C
Junction temperature, T
J
+150 °C
Electrostatic discharge (ESD)
Human body model (HBM) 2000 V
ratings TLV3201
Electrostatic discharge (ESD)
Human body model (HBM) 1000 V
ratings TLV3202
(1) Stresses beyond those listed under absolute maximum ratings may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under recommended operating
conditions is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) All voltage values are with respect to the network ground terminal.
(3) Short-circuit to ground.
2 Copyright © 2012, Texas Instruments Incorporated