Datasheet
www.ti.com
TLV301x
V
IN
V
OUT
R
PULLUP
(1)
V+
5 V
V
REF
R
1
39 kΩ
R2
560 kΩ
REF
V = 0.38 V
HYST
(1) Use R with the TLV3011 only.
PULLUP
–
+
Applications
Battery-Level Detect
R + R
1 2
R
2
Battery Okay trip voltage = 1.242
Battery
Okay
R1
1 MΩ
R2
2 MΩ
R
PULLUP
(1)
TLV301x
When the battery voltage drops below 1.9 V,
the Battery Okay output goes low.
(1) Use R with the TLV3011 only.
PULLUP
REF
1.242 V
+
–
+
–
TLV3011-EP , TLV3012-EP
SGLS349 – OCTOBER 2006
APPLICATION INFORMATION (continued)
Figure 23. Adding Hysteresis
V
HYST
sets the value of the transition voltage required to switch the comparator output by increasing the
threshold region, thereby reducing sensitivity to noise.
The low power consumption and 1.8-V supply voltage of the TLV3011 make it an excellent candidate for
battery-powered applications. Figure 24 shows the TLV3011 configured as a low battery level detector for a 3-V
battery.
Figure 24. TLV3011 Configured as Low Battery Level Detector