Datasheet

TLV2760, TLV2761, TLV2762, TLV2763, TLV2764, TLV2765
FAMILY OF 1.8 V MICROPOWER RAIL-TO-RAIL INPUT/OUTPUT
OPERATIONAL AMPLIFIERS WITH SHUTDOWN
SLOS326F JUNE 2000 REVISED AUGUST 2013
4
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage, V
DD
(see Note 1) 4 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Differential input voltage range, V
ID
±V
DD
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Input current range, I
I
±10 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Output current range, I
O
±10 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Continuous total power dissipation See Dissipation Rating Table. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating free-air temperature range, T
A
: C-suffix 0°C to 70°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
I-suffix 40°C to 85°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Maximum junction temperature, T
J
150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage temperature range, T
stg
65°C to 150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds 260°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTE 1: All voltage values, except differential voltages, are with respect to GND
DISSIPATION RATING TABLE
PACKAGE
Θ
JC
Θ
JA
T
A
25°C T
A
= 85°C
PACKAGE
Θ
JC
(
°
C/W)
Θ
JA
(
°
C/W)
T
A
25 C
POWER RATING
T
A
= 85 C
POWER RATING
D (8) 38.3 176 710 mW 369 mW
D (14) 26.9 122 1022 mW 531 mW
D (16) 25.7 114 1090 mW 567 mW
DBV (5) 55 324 385 mW 201 mW
DBV (6) 55 294 425 mW 221 mW
DGK(8) 54.2 260 481 mW 250 mW
DGS(10) 54.1 258 485 mW 252 mW
N (14,16) 32 78 1600 mW 833 mW
P 41 104 1200 mW 625 mW
PW (14) 29.3 174 720 mW 374 mW
PW (16) 28.7 161 774 mW 403 mW
recommended operating conditions
MIN MAX UNIT
Supply voltage V
Single supply 1.8 3.6
V
Supply voltage, V
DD
Split supply ±0.8 ±1.8
V
Common-mode input voltage range, V
ICR
0.2 V
DD
+0.2 V
Operating free air temperature T
C-suffix 0 70
°C
Operating free-air temperature, T
A
I-suffix
40 85
°C
V
V
DD
< 2.7 V 0.75 V
DD
Shutdown on/off voltage level (see Note 2)
V
IH
V
DD
= 2.7 to 3.6 V
2
V
/g( )
V
IL
0.6
NOTE 2: Relative to GND