Datasheet

TLV2731, TLV2731Y
Advanced LinCMOS RAIL-TO-RAIL
LOW-POWER SINGLE OPERATIONAL AMPLIFIERS
SLOS198A AUGUST 1997 REVISED MARCH 2001
17
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
TYPICAL CHARACTERISTICS
Figure 23
LARGE-SIGNAL DIFFERENTIAL
VOLTAGE AMPLIFICATION
†‡
vs
FREE-AIR TEMPERATURE
T
A
Free-Air Temperature °C
Large-Signal Differential Voltage
A
VD
Amplification V/mV
50 25 0 25 50 75 100
R
L
= 600
10
3
10
2
0.1
V
DD
= 3 V
V
IC
= 1.5 V
V
O
= 0.5 V to 2.5 V
75 125
10
1
1
R
L
= 1 M
Figure 24
LARGE-SIGNAL DIFFERENTIAL
VOLTAGE AMPLIFICATION
†‡
vs
FREE-AIR TEMPERATURE
T
A
Free-Air Temperature °C
Large-Signal Differential Voltage A
VD
Amplification V/mV
50 25 0 25 50 75 100 125
10
3
10
2
0.1
75
V
DD
= 5 V
V
IC
= 2.5 V
V
O
= 1 V to 4 V
R
L
= 1 M
R
L
= 600
10
1
1
Figure 25
Output Impedance
f Frequency Hz
OUTPUT IMPEDANCE
vs
FREQUENCY
z
o
10
1
0.1
1000
100
10
2
10
3
10
4
10
5
10
6
A
V
= 100
A
V
= 10
A
V
= 1
V
DD
= 3 V
T
A
= 25°C
Figure 26
Output Impedance
f Frequency Hz
OUTPUT IMPEDANCE
vs
FREQUENCY
z
o
10
1
0.1
1000
100
10
2
10
3
10
4
10
5
10
6
A
V
= 100
A
V
= 10
A
V
= 1
V
DD
= 5 V
T
A
= 25°C
Data at high and low temperatures are applicable only within the rated operating free-air temperature ranges of the various devices.
For all curves where V
DD
= 5 V, all loads are referenced to 2.5 V. For all curves where V
DD
= 3 V, all loads are referenced to 1.5 V.