Datasheet

www.ti.com
ABSOLUTE MAXIMUM RATINGS
DISSIPATION RATING TABLE
RECOMMENDED OPERATING CONDITIONS
TLV2620, TLV2621
TLV2622, TLV2623
TLV2624, TLV2625
SLOS251D DECEMBER 2000 REVISED JANUARY 2005
over operating free-air temperature range (unless otherwise noted)
(1)
V
DD
Supply voltage
(2)
6 V
V
ID
Differential input voltage ± V
DD
V
I
Input voltage range
(2)
+1 to V
DD
+ 0.2 V
I
I
Input current (any input) ± 10 mA
I
O
Output current ± 40 mA
Continuous total power dissipation See Dissipation Rating Table
T
A
Operating free-air temperature range: I-suffix -40 ° C to 125 ° C
T
J
Maximum junction temperature 150 ° C
T
stg
Storage temperature range -65 ° C to 150 ° C
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds 260 ° C
(1) Stresses beyond those listed under absolute maximum ratings may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under recommended operating
conditions is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) All voltage values, except differential voltages, are with respect to GND.
θ
JC
θ
JA
T
A
25 ° C T
A
= 125 ° C
PACKAGE
( ° C/W) ( ° C/W)
POWER RATING POWER RATING
D (8) 38.3 176 710 mW 142 mW
D (14) 26.9 122.3 1022 mW 204.4 mW
D (16) 25.7 114.7 1090 mW 218 mW
DBV (5) 55 324.1 385 mW 77.1 mW
DBV (6) 55 294.3 425 mW 85 mW
DGK (8) 54.2 259.9 481 mW 96.1 mW
DGS (10) 54.1 259.7 485 mW 97 mW
N (14, 16) 32 78 1600 mW 320.5 mW
P (8) 41 104 1200 mW 240.4 mW
PW (14) 29.3 173.6 720 mW 144 mW
PW (16) 28.7 161.4 774 mW 154.9 mW
MIN MAX UNIT
Single supply 2.7 5.5
V
DD
Supply voltage V
Split supply ± 1.35 ± 2.75
V
ICR
Common-mode input voltage range 1 V
DD
+0.2 V
T
A
Operating free-air temperature I-suffix -40 125 ° C
V
IL
0.4
Shutdown on/off voltage level
(1)
V
V
IH
2
(1) Relative to GND.
4