Datasheet

TLV2541, TLV2542, TLV2545
2.7-V TO 5.5-V, LOW-POWER, 12-BIT, 140/200 KSPS,
SERIAL ANALOG-TO-DIGITAL CONVERTERS WITH AUTOPOWER DOWN
SLAS245E MARCH 2000 REVISED APRIL 2010
8
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
POST OFFICE BOX 1443
HOUSTON, TEXAS 772511443
0.95 mA
2 μA
I
CC
With 1-μF/0.1-μF Capacitor Between Supply and Ground
t
(
Powerdown
)
Powerdown time S
0.5 μS
2 mS
V
DD
= 2.7 V
1 μA
5 μA
V
DD
= 5 V
1 μA
1.5 mA
Table 1. Modes of Operation and Data Throughput
CONTROL PIN(s)/DEVICE
MAX SCLK (MHz)
(50/50 duty cycle)
APPROXIMATE
CONVERSION
THROUGHPUT
(ksps)
V
DD
= 2.7 V V
DD
= 4.5 V V
DD
= 2.7 V V
DD
= 4.5 V
CS control only (TLV2541 only)
For SPI interface
10 15 175 200
For DSP interface (Use CS as FS)
5 8 140 175
CS and FS control (TLV2541 only)
§
DSP interface 15 20 200 200
See Figure 29(a).
See Figure 29(b).
§
See Figure 29(c).
absolute maximum ratings over operating free-air temperature (unless otherwise noted)
Supply voltage range, GND to V
DD
0.3 V to 6.5 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Analog input voltage range 0.3 V to V
DD
+ 0.3 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Reference input voltage V
DD
+ 0.3 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Digital input voltage range 0.3 V to V
DD
+ 0.3 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating
virtual junction temperature range, T
J
40°C to 150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating free-air temperature range, T
A
:C 0°C to 70°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
I 40°C to 85°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage temperature range, T
stg
65°C to 150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds 260°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.